Vaillant boiler fault codes

Vaillant ecoTEC boilers show faults as F. followed by a number. Find your code below to see what it means, what you can safely check, and when you need a Gas Safe engineer.

Before you call anyone

Most winter callouts for Vaillant boilers are F.22 (low pressure) and F.28 (failed to light). Both often have a simple cause you can check yourself: the pressure gauge, your gas supply, and whether the condensate pipe outside has frozen.

CodeWhat it meansModelsCan you fix it?
F.22Low water pressure in the system.ecoTEC plusUsually yes
F.28No flame detected when the boiler tried to light.ecoTEC plusChecks first
F.75No pressure rise detected when the pump started.ecoTEC plusChecks first
F.29The flame went out during use and the boiler could not relight.ecoTEC plusChecks first
F.83No temperature change detected when the burner started.ecoTEC plusChecks first
F.23The temperature difference between flow and return is too great.ecoTEC plusNo, engineer only
F.72Flow or return temperature sensor fault.ecoTEC plusNo, engineer only
F.20The safety cut-out has stopped the gas because the boiler overheated.Vaillant boilers (Vaillant's fault code list)No, engineer only
F.25The flue gas temperature is too high.ecoTEC plusNo, engineer only
F.27A flame signal was detected while the burner should be off.ecoTEC plusNo, engineer only
F.61A fault in the gas valve control.ecoTEC plusNo, engineer only
F.62The flame went out later than expected after switch-off.ecoTEC plusNo, engineer only
conNo communication with the PCB.ecoTEC plusNo, engineer only
F.00Flow temperature sensor interruption.ecoTEC plusNo, engineer only
F.01Return temperature sensor interruption.ecoTEC plusNo, engineer only
F.10Flow temperature sensor short circuit.ecoTEC plusNo, engineer only
F.11Return temperature sensor short circuit.ecoTEC plusNo, engineer only
F.13Warm start sensor or cylinder sensor short circuit.ecoTEC plusNo, engineer only
F.24Safety switch-off: temperature rise too fast.ecoTEC plusNo, engineer only
F.32Fan fault.ecoTEC plusNo, engineer only
F.49eBUS fault.ecoTEC plusNo, engineer only
F.63EEPROM fault.ecoTEC plusNo, engineer only
F.64Electronics or temperature sensor fault.ecoTEC plusNo, engineer only
F.65Electronics temperature fault.ecoTEC plusNo, engineer only
F.67Electronics or flame fault.ecoTEC plusNo, engineer only
F.68Unstable flame signal.ecoTEC plusNo, engineer only
F.70Invalid device specific number (DSN).ecoTEC plusNo, engineer only
F.71Flow temperature sensor fault.ecoTEC plusNo, engineer only
F.73Water pressure sensor signal in the wrong range (too low).ecoTEC plusNo, engineer only
F.74Water pressure sensor signal outside the correct range (too high).ecoTEC plusNo, engineer only
F.76Overheating protection on the primary heat exchanger has responded.ecoTEC plusNo, engineer only
F.77Flue non-return flap or condensate pump fault.ecoTEC plusNo, engineer only
F.85Flow and return temperature sensors incorrectly installed.ecoTEC plusNo, engineer only
F.87Ignition transformer not connected.ecoTEC plusNo, engineer only
F.88Gas valve not connected.ecoTEC plusNo, engineer only
F.89Incorrect pump detected.ecoTEC plusNo, engineer only