Smell gas? Leave the property and call the National Gas Emergency line on 0800 111 999
BoilerCodes

Worcester Bosch boiler fault codes

Worcester Bosch Greenstar boilers show a two-character fault code such as EA, E9 or C6. Newer Greenstar 8000 models can show numbered faults instead, such as 2980. Find your code below.

Before you call anyone

EA is the Worcester code people search for most. Worcester says it can mean no gas supply, a blocked or frozen condensate pipe, or a blocked flue.

CodeWhat it meansModelsCan you fix it?
EAFlame not detected.Greenstar CDi ClassicChecks first
E9The safety temperature limiter in the heating flow has tripped.Greenstar CDi ClassicNo, engineer only
C6Fan speed too low.Greenstar CDi ClassicNo, engineer only
A8Lost communication with the boiler's controls.Greenstar CDi ClassicNo, engineer only
F7Flame detected even though the boiler is switched off.Greenstar CDi ClassicNo, engineer only
FAFlame detected after the gas was shut off.Greenstar CDi ClassicNo, engineer only
2980Fault 2980 on Greenstar 8000 models.Greenstar 8000+No, engineer only
214Fan shut down during safety time.Greenstar 4000No, engineer only
224Varies by model: maximum flue gas thermostat or heat exchanger maximum thermostat has activated (Greenstar 4000); safety temperature limiter has tripped (Greenstar 8000 Life).Greenstar 4000, Greenstar 8000 LifeNo, engineer only
227No flame signal after ignition.Greenstar 4000, Greenstar 8000 LifeChecks first
228Flame signal without flame present.Greenstar 4000, Greenstar 8000 LifeNo, engineer only
229Flame failed during burner operation.Greenstar 8000 LifeChecks first
232Boiler locked by external switching contact.Greenstar 4000No, engineer only
306Flame signal after closing the fuel supply.Greenstar 8000 LifeNo, engineer only
360Incompatible code plug.Greenstar 8000 LifeNo, engineer only
815Low loss header temperature sensor faulty.Greenstar 8000 LifeNo, engineer only
1010No BUS communication: EMS bus cable not connected correctly or damaged.Greenstar 8000 LifeNo, engineer only
1017Water pressure too low.Greenstar 8000 LifeUsually yes
1021Hot water temperature sensor defective.Greenstar 8000 LifeNo, engineer only
1037Outside temperature sensor defective.Greenstar 8000 LifeNo, engineer only
1065Pressure sensor defective or not connected.Greenstar 8000 LifeNo, engineer only
1068Outside temperature sensor defective.Greenstar 8000 LifeNo, engineer only
1073Short circuit of the flow temperature sensor.Greenstar 8000 LifeNo, engineer only
1074No signal from the flow temperature sensor.Greenstar 8000 LifeNo, engineer only
A7Hot water temperature sensor defective.Greenstar CDi ClassicNo, engineer only
b1Code plug not detected.Greenstar CDi ClassicNo, engineer only
E2Central heating flow temperature sensor defective.Greenstar CDi ClassicNo, engineer only
F0Internal error.Greenstar CDi ClassicNo, engineer only

Sources