Potterton boiler fault codes

Potterton is part of the same company as Baxi, and Potterton Assure boilers appear in Baxi's own fault code table. Codes show as an E and three numbers, and E133 often alternates as E1 then 33.

Before you call anyone

E133 is the most common Potterton code. Potterton says it is the code you'll see when the condensate pipe has frozen.

CodeWhat it meansModelsCan you fix it?
E133Gas supply or ignition fault, often a frozen condensate pipe.Potterton Assure (in Baxi's fault table)Checks first
E118Low water pressure (below 0.5 bar).Potterton Assure (in Baxi's fault table)Usually yes
E110Overheat: the safety thermostat has tripped.Potterton Assure (in Baxi's fault table)No, engineer only
E125Water circulation fault.Potterton Assure (in Baxi's fault table)No, engineer only
E160Fan fault.Potterton Assure (in Baxi's fault table)No, engineer only
E09Gas valve connection fault.Potterton Assure (in Baxi's fault table)No, engineer only
E10External probe fault.Potterton Assure (in Baxi's fault table)No, engineer only
E12Differential water flow switch fault (still open).Potterton Assure (in Baxi's fault table)No, engineer only
E13Differential water flow switch fault (still closed).Potterton Assure (in Baxi's fault table)No, engineer only
E15Gas valve command fault.Potterton Assure (in Baxi's fault table)No, engineer only
E20Central heating temperature sensor fault: short circuit or open circuit.Potterton Assure (in Baxi's fault table)No, engineer only
E28Flue temperature sensor fault: short circuit or open circuit.Potterton Assure (in Baxi's fault table)No, engineer only
E40Return central heating temperature sensor fault: short circuit or open circuit.Potterton Assure (in Baxi's fault table)No, engineer only
E50Hot water temperature sensor fault (tank boiler): short circuit or open circuit.Potterton Assure (in Baxi's fault table)No, engineer only
E83No communication.Potterton Assure (in Baxi's fault table)No, engineer only
E84No communication.Potterton Assure (in Baxi's fault table)No, engineer only
E85No communication.Potterton Assure (in Baxi's fault table)No, engineer only
E86No communication.Potterton Assure (in Baxi's fault table)No, engineer only
E87No communication.Potterton Assure (in Baxi's fault table)No, engineer only
E103Safety Assist battery is exhausted.Potterton Assure (in Baxi's fault table)No, engineer only
E104Faulty Safety Assist PCB.Potterton Assure (in Baxi's fault table)No, engineer only
E107PCBs not synchronised.Potterton Assure (in Baxi's fault table)No, engineer only
E109Precirculation alarm.Potterton Assure (in Baxi's fault table)No, engineer only
E128Safety error for frequent loss of flame.Potterton Assure (in Baxi's fault table)No, engineer only
E129Safety error for frequent loss of flame with maximum correction during ignition.Potterton Assure (in Baxi's fault table)No, engineer only
E130Flue thermostat sensor tripped (lockout).Potterton Assure (in Baxi's fault table)No, engineer only
E134Gas valve open for too long without gas.Potterton Assure (in Baxi's fault table)No, engineer only
E135Internal error.Potterton Assure (in Baxi's fault table)No, engineer only
E154Plausibility test (flow/return).Potterton Assure (in Baxi's fault table)No, engineer only
E270Dry fire.Potterton Assure (in Baxi's fault table)No, engineer only
E317Wrong power supply electrical frequency (Hz) (also shown as 162).Potterton Assure (in Baxi's fault table)No, engineer only
E321Hot water temperature sensor fault (also shown as 163).Potterton Assure (in Baxi's fault table)No, engineer only
E384False flame (parasitic flame) (also shown as 164).Potterton Assure (in Baxi's fault table)No, engineer only
E385Under voltage (also shown as 165).Potterton Assure (in Baxi's fault table)No, engineer only
E430Water pressure temporary fault or test failed (also shown as 166).Potterton Assure (in Baxi's fault table)No, engineer only