Viessmann boiler fault codes

Viessmann Vitodens boilers show a letter and a number, such as F4. These meanings come from Viessmann's Vitodens 100-W instructions; other Vitodens models can use different codes, so check your manual.

Before you call anyone

F4 is the Viessmann code people search for most. Viessmann says it's the code you're likely to see on a Vitodens when the condensate pipe has frozen.

CodeWhat it meansModelsCan you fix it?
F4No flame signal.Vitodens 100-W (B1HC/B1KC)Checks first
F2Burner fault: the temperature limiter has responded.Vitodens 100-W (B1HC/B1KC)No, engineer only
F3Flame signal already present when the burner starts.Vitodens 100-W (B1HC/B1KC)No, engineer only
F8Fuel valve closes too late.Vitodens 100-W (B1HC/B1KC)No, engineer only
F9Fan speed too low when the burner starts.Vitodens 100-W (B1HC/B1KC)No, engineer only
0CMains voltage too low.Vitodens 100-W (B1HC/B1KC)No, engineer only
0ACO limiter has responded (CO concentration too high), or gas pressure switch has responded (gas pressure too low).Vitodens 100-W (B1HC/B1KC)No, engineer only
5ALead break, flow sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
10Short circuit, outside temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
18Lead break, outside temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
30Short circuit, boiler water temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
38Lead break, boiler water temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
50Short circuit, cylinder temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
51Short circuit, outlet temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
52Short circuit, flow sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
58Lead break, cylinder temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
59Lead break, outlet temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
A3Flue gas temperature sensor incorrectly positioned.Vitodens 100-W (B1HC/B1KC)No, engineer only
A9Communication error, OpenTherm device.Vitodens 100-W (B1HC/B1KC)No, engineer only
b0Short circuit, flue gas temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
b8Lead break, flue gas temperature sensor.Vitodens 100-W (B1HC/B1KC)No, engineer only
E3Fault in safety chain.Vitodens 100-W (B1HC/B1KC)No, engineer only
E5Internal fault.Vitodens 100-W (B1HC/B1KC)No, engineer only
F0Internal fault.Vitodens 100-W (B1HC/B1KC)No, engineer only
F1Maximum flue gas temperature exceeded.Vitodens 100-W (B1HC/B1KC)No, engineer only
FAFan idle state not reached.Vitodens 100-W (B1HC/B1KC)No, engineer only
FCElectrical fan control (control unit) faulty.Vitodens 100-W (B1HC/B1KC)No, engineer only
FdBurner control unit fault.Vitodens 100-W (B1HC/B1KC)No, engineer only
FFBurner control unit fault.Vitodens 100-W (B1HC/B1KC)No, engineer only