Smell gas? Leave the property and call the National Gas Emergency line on 0800 111 999
BoilerCodes
EA
Worcester Bosch fault code

Worcester Bosch EA: flame not detected

Check these first, then call an engineer

The boiler tried to light but didn't detect a flame. Worcester Bosch lists three common causes: no gas supply or low gas pressure, a blocked condensate outlet (often ice in winter), or a blocked flue. Worcester also says a blocked condensate pipe can make the boiler lock out repeatedly with EA and make gurgling sounds.

What you can safely do

  1. Check your gas supply: does your hob work? If there's no gas, Worcester says to contact your gas supplier.
  2. If it is safe to do so, check the condensate pipe outlet outside for ice or other blockages. To thaw it, use a hot water bottle, a microwaveable heat pack or a cloth soaked in hot water. Don't use boiling water.
  3. If it is safe to do so, check the flue outlet outside for damage or blockages.
  4. Reset the boiler as your user manual describes. After thawing a frozen condensate pipe, Worcester says to wait two or three minutes for the boiler to restart.

Call a Gas Safe engineer if

  • EA comes back after these checks.
  • You can see damage to the flue.
  • You smell gas at any point. Leave the property and call 0800 111 999.
Find a Gas Safe engineer near you Opens the official Gas Safe Register search.

Applies to: Greenstar CDi Classic. Codes can differ between models, so check your manual.

What EA means on each Worcester Bosch model

From Worcester Bosch's own fault tables. Your model name is usually on the front of the boiler or in the user manual.

ModelMeaning
Greenstar CDi ClassicFlame not detected

Common questions about Worcester Bosch EA

What does EA mean on a Worcester Bosch boiler?

Worcester Bosch describes EA as flame not detected: the boiler tried to light and couldn't sense a flame.

Can a frozen condensate pipe cause EA?

Yes. Worcester lists a blocked condensate outlet as one of the causes and says the boiler may repeatedly lock out and show EA.

How do I reset a Worcester Bosch boiler?

It depends on the model. On the Greenstar CDi Classic you press the reset button for three seconds; on the Greenstar i you press reset once. Your user manual shows the exact steps.

Nearby Worcester Bosch codes

See all 28 Worcester Bosch codes

Sources